- Tensile Testing Machines and Accessories
- Grips and Devices for Tensile Testing Machines
- Impact Testers
- Hardness testers
- TB 5056-02
- TB 5004, TB 5004-03
- TB 5015
- TB 5015A
- TB 5015-01C
- TBP 5013
- TR 5006M
- TR 5014
- TR 5014-01М
- TR 5043
- TR 5018M
- TR 5018MS
- TR 5018M-01
- TR 5018PA
- TRP 5011
- TRS 5009-01
- TPC 5019MS
- 2143 TRS-M
- IT 5010, IT 5010-01M
- IT 5038-01, IT 5038-02
- TV 5214A
- TV 5214-01C
- TVM 5215A
- TVM 5215AC
- UT 5021 PA
- UT 5021MS
- UT 5021M-01
- UT 5021M-01S
- 2124 TML
- TIR 2033 (Shore A)
- TIR 2033A (Shore A)
- TIR 2033 (Shore D)
- TIR 2033A (Shore D)
- Metallography Equipment
- Inprocess Testing Machines
- Machines for Testing Road and Building Materials
- Spring Testing Machines
- Friction and Wear Testing Machines
- Machines and Systems for Temperature Testing
- Portable Dynamometers
- General Purpose Dynamometers
- Standard Hardness Test Blocks
- Shoe testing tools
TB 5015-01C Tochline
Brinell hardness tester
The Brinell hardness tester TB 5015-01C is designed to measure the hardness of metals and alloys according to the Brinell method.
The instrument for measuring hardness (hardness tester) according to the Brinell method of TB 5015-01C according to GOST 9012 with an electromechanical drive and an electronic load control system is a stationary measuring tool. Principle of operation - Automatic loading process. - The device has an electromechanical drive with a motor, providing a smooth exit to the main load, its maintenance for a given time and removal. The presence of a force sensor with feedback, for accurate task and maintenance of the test load, the absence of suspended loads. - The test load is selected on the control panel of the electronic digital unit (hereinafter referred to as the Central Bank). Squeezing of the sample is carried out manually by turning the lifting screw. - The task, endurance and removal of the main loads are displayed on the control panel of the Central Bank in automatic mode. - The design of the device will allow testing samples up to 200 mm high.
Features of the digital-to-digital unit:
• Interactive work;
• Test load selection;
• Setting the exposure time under load;
• Display of loading and holding process;
• Ergonomic management.
SPECIFICATIONS | ||||||||
Test loads and hardness measuring ranges according to Brinell scales in accordance with GOST 9012-59, HBW: | ||||||||
2,5/62,5 (load 613 N)
| from 32 to 218 | |||||||
5/62,5 (load 613 N)
| from 8 to 50 | |||||||
2,5/187,5 (load 1839 N)
| from 95 to 650 | |||||||
5/125 (load 1226 N)
| from 16 to 100 | |||||||
5/250 (load 2452 N)
| from 32 to 218 | |||||||
5/750 (load 7355 N)
| from 95 to 650 | |||||||
10/100 (load 981 N)
| from 3 to 20 | |||||||
10/250 (load 2452 N)
| from 8 to 50 | |||||||
10/500 (load 4903 N)
| from 16 to 100 | |||||||
10/1000 (load 9807 N)
| from 32 to 218 | |||||||
10/1500 (load 14710 N)
| from 48 to 220 | |||||||
10/3000 (load 29420 N)
| from 95 to 650 | |||||||
The main test load according to Brinell, N:
| 29420, 14710, 9807, 7355, 4903, 2452, 1839, 1226, 981, 613 | |||||||
Limits of permissible error of test loads by the Brinell method,%, no more:
| ± 1,0 | |||||||
The distance from the top of the test tip to the working plane is adjustable, mm:
| up to 200 | |||||||
The distance from the axis of the test tip to the wall of the case, limiting the size of the test product, not less than, mm:
| 130 | |||||||
Power supply:
| 220V; 50Hz | |||||||
Power consumption of the device, no more than:
| 100W | |||||||
Overall dimensions (length x width x height), mm, no more than:
| 530х187х758 | |||||||
Weight, kg, no more than:
| 135 |
Limits of permissible absolute error of hardness measurement according to Brinell scales: | ||||||||
Hardness scale designations | Intervals for measuring hardness, units hardness | |||||||
11±9 | 35±15 | 75±25 | 125±25 | 200±50 | 300±50 | 400±50 | 550±100 | |
The limits of permissible absolute errors of the hardness tester, (±), units hardness | ||||||||
HBW 10/100 | 0,6 | - | - | - | - | - | - | - |
HBW 5/62; HBW 10/250 | 0,6 | 1,5 | - | - | - | - | - | - |
HBW 5/125; HBW 10/500 | 0,6 | 1,5 | 3,0 | - | - | - | - | - |
HBW 2,5/62,5; HBW 5/250; HBW 10/1000; HBW 10/1500 | - | 1,5 | 3,0 | 4,5 | 7,5 | - | - | - |