8(800) 350-02-48

Free call in Russia

Sales department +7 (812) 612-30-03

Department of metrology +7(4932)   23-28-44

Design department +7(4932)   23-67-15

Testing Instruments Factory, LLC modernizes and repairs testing equipment previously released from production
Production of our goods on the territory of the Russian Federation is confirmed by the conclusion of Ministry of Industry and Trade Russia according to expert opinion of Ivanovo Chamber of Commerce and Industry   Read more...
Since June 2016 our factory has extended a warranty period for its products
up to 2 years

TVM 5215A Tochline

Micro Vickers hardness tester

The micro-Vickers hardness tester TVM 5215A is designed to measure the hardness of metals and alloys according to the Vickers method according to GOST R 8.695-2009 (ISO 6507-1: 2005),
GOST 2999-75

The micro-Vickers hardness tester TV 5215A is a stationary measuring instrument consisting of a load application system and a measuring unit.
The principle of operation of the hardness tester is based on the static indentation of the diamond pyramidal tip with subsequent measurement of the lengths of the diagonals of the reconstructed print.
The device has a large touch screen, an electromechanical drive to set loads, an integrated optical system, and an automatic rotary turret.
When measured according to the Vickers method, the system for applying the load of devices provides the application of loads of 0.098; 0, 245; 0.49; 0.98; 1.96; 2.94; 4.9; 9.8; 19.6N
The design of the hardness tester is reliably protected from unauthorized access, adjustment of factory settings and software.
Special software for the built-in microprocessor of the hardness tester software is used to enter the initial parameters and start the load application cycle, record, store and statistically process the measurement results and display them on the digital liquid crystal display.

Features of the electronic digital unit:
• Interactive work;
• Hardness scale selection;
• Setting the exposure time under load;
• Display of loading process and holding time;
• Sorting into hardness groups LESS, NORMAL, MORE;
• Statistical processing of a series of measurements;
• Saving results in the memory of CB;
• Auto-tuning (calibration) according to standard measures of hardness;
• Conversion of hardness values ​​to other scales and methods;
• Touch control;
• Multi-user interface;
• Saving Results to a USB Flash Drive.
• Semi-automatic optical system for measuring the size of the print according to the Vickers method with automatic data transfer and obtaining hardness on the display.

SPECIFICATIONS
Test loads on Vickers scales, N: 0,098; 0, 245; 0,49; 0,98; 1,96; 2,94; 4,9; 9,8; 19,6
Vickers hardness measuring range, HV: from 8 to 3000
Limits of permissible relative error in measuring hardness on Vickers scales, %: ±3
Limits of permissible absolute measurement error of the measuring microscope, mm: ± 0.001
Sizes of X-Y coordinate table, mm: 100х100
X-Y stroke of the coordinate table, mm: 25х25
The maximum height of the sample, mm: 80
Depth of a working zone, mm: 95
Overall dimensions (length x width x height), mm, no more than: 405x290x480
Weight, kg, no more than: 25