- Tensile Testing Machines and Accessories
- Grips and Devices for Tensile Testing Machines
- Impact Testers
- Hardness testers
- Metallography Equipment
- Inprocess Testing Machines
- Machines for Testing Road and Building Materials
- Spring Testing Machines
- Friction and Wear Testing Machines
- Machines and Systems for Temperature Testing
- Portable Dynamometers
- General Purpose Dynamometers
- Standard Hardness Test Blocks
- Shoe testing tools
ZKRE-200KS Captures wedge lever eccentric
Captures are designed to secure and hold flat or cylindrical specimens during tensile testing.
Materials for tests: metals, including heat-treated, plastics, including carbon fiber and other materials within the technical capabilities of the grippers.
Sample types: flat, cylindrical, wire, rods of round, hexagonal and square sections.
The grippers are equipped with a large set of clamping jaws with interchangeable inserts made of materials with high hardness, roller cassette guides for moving clamping jaws and lever-eccentric jaw drive.
The grips are adapted to the design of explosive machines: IR 5143-200 and can be delivered to machines IR 5113-100 and IR 5145-500.
Distinctive features of ZKRE-200KS captures are:
- wide range of test samples;
- reliable fastening of samples with a high degree of hardness;
- convenience and speed when fixing samples.
The construction of the grips ZKRE-200KS is protected by patents No. 2116643, No. 2222799, No. 2282173, No. 2243534.
TECHNICAL SPECIFICATIONS | |
Maximum test load, kN | 200 |
The initial thickness of the sample (type 1 and 2 according to GOST 11701 and GOST 1497), mm | from 0.5 to 12.0 |
Initial diameters of cylindrical samples and rods, mm | from 4.0 to 15.0 |
The maximum diameter of the sample head (type 6 and 7 according to GOST 1497), mm | 22,0 |
Diameter of the test wire (including carbon), mm | from 1.0 to 8.0 |
Thickness of thin sheets and tapes, mm | from 0.2 to 3.0 |
Cross-sectional area of bars of hexagonal and square sections, not more than, mm2 | 200 |
Overall dimensions of one capture (without handles) no more, mm | 190x285x245 |
Weight, no more than, kg | |
set of grips (without sponge) |
52 |
sets of replacement parts (5 sets of sponges) |
18 |